AVSupply

4575 Ruffner St., San Diego, CA 92111 | P: 858.565.1101 | T: 800.284.2288 | F: 858.565.7845 | E: sales@avsupply.com

#1 ELECTRONICS DISTRIBUTOR IN WHOLESALE | GOVERNMENT/GSA | EDUCATION | INTERNATIONAL

Comnet FDC10 SERIES Bi-Directional Contact Closure

Comnet FDC10 SERIES Bi-Directional Contact Closure

Offering Wholesale, OEM, USA / International, GSA Government / Educational, Reseller / Retail, & Quantity Prices and Specifications / Datasheets, Installation Guides, and Operational Manuals.


Price Documents
Transmits a single contact closure in one or two directions
Distances up to 69 km (43 miles)
24 VDC, 0.5 amp relay output, normally open
Point-to-Point transmission architecture
No in-field electrical or optical adjustments required
Bi-Color (Red/Green) Carrier Detect and Relay closed indicators
Relay contact for Carrier Detect (normally closed with carrier present)
Automatic resettable solid-state current limiters
CONTACTS
Contact Interface: Response Time: 0.5 msec
Input: Dry Contact Closure
Output: SPST Relay, 0.5 A Contact Rating - normally open
WAVELENGTH A = 1310/1550 nm
B = 1550/1310 nm
NUMBER OF FIBERS 1
CONNECTORS
Optical: ST
Contact and Power: Terminal Block
LED INDICATORS Contact Relay
Carrier Detect
ELECTRICAL & MECHANICAL
Power:
Surface Mount: 8-15 VDC @ 80 mA
Current Protection: Automatic Resettable
Solid-State Current Limiters
Circuit Board: Meets IPC Standard
Size (in./cm) (LxWxH)
Surface Mount: 4.0 x 3.7 x 1.0 in., (10.4 x 9.5 x 2.7 cm)
Shipping Weight: <1 lb./0.5 kg
ENVIRONMENTAL
MTBF: >100,000 hours
Operating Temp: -40° C to 75° C
Storage Temp: -40° C to 85° C
Relative Humidity: 0% to 95% (non-condensing)
May be extended to condensation conditions by adding suffix '-C' to model number for conformal coating.
9 Volt DC Plug-in Power Supply, 90-264 VAC, 50/60 Hz (Included)
Lifetime Warranty

The ComNetTM FDC10 Series bi-directional contact closure transceiver provides bi-directional transmission of contact closure over one multimode or single mode optical fiber. The transceiver has a contact input and a 0.5 amp contact output. Plug-and-play design ensures ease of installation requiring no electrical or optical adjustments. The bi-directional contact closure module has two relay outputs and one relay input. One relay output follows the "relay input" at the remote end. When the remote "relay input" is shorted, the local relay output is closed and vice-versa. The second relay output is closed when "carrier" is detected from the remote end, this indicates that the optical fiber is connected and that the remote end has power and is operating. The relay position (open for RED and closed for GREEN) is indicated by separate bi-color indicators for each relay.

Tested and certified by an independent laboratory for full compliance with the environmental requirements (ambient operating temperature, mechanical shock, vibration, humidity with condensation, high-line/low-line voltage conditions and transient voltage protection) of NEMA TS-1/TS-2 and the Caltrans Specification for Traffic Signal Control Equipment.

Voltage transient protection on all power and signal input/output lines provides unconditional protection from power surges and other voltage transient events.

Similar Models:

FDC10M1(A): Contact Closure Transceiver (1310/1550 nm), Multimode 62.5/125μm, 16 dB, 16 km (10 miles), Rack Slots NA
FDC10M1(B): Contact Closure Transceiver(1550/1310 nm), Multimode 62.5/125μm, 16 dB, 16 km (10 miles), Rack Slots NA
FDC10S1(A): Contact Closure Transceiver (1310/1550 nm), Single Mode 9/125μm, 16 dB, 69 km (43 miles), Rack Slots NA
FDC10S1(B): Contact Closure Transceiver(1550/1310 nm), Single Mode 9/125μm, 16 dB, 69 km (43 miles), Rack Slots NA