stc-gec202a.jpg View Larger Image (in new window)

Sentech : STC-GEC202A

By: Sentech
Industrial, USB, & Medical Cameras
Contact us for lowest price (800) 284-2288, (858) 565-1101,, or fax (858) 300-4193
1/1.8" UXGA (1600 x 1200), 2 MP, color, GigE camera, w/ IR cut filter

The STC-GEC202A is part of Sentech's Standard GigE camera line. It features a 1/1.8" color UXGA sensor, 15fps and communication over a 6 pin Hirose or Ethernet connector. The STC-GEC202A boasts precision housing with accurate CCD alignment, a DC Auto Iris Lens Driver, a user-programmable Area of Interest (AOI) and a Gamma Table that can be imported. This camera meets all industry standards for GigE Vision® and GenICam™.

STC-GEC202A features include:

  • 1/1.8" CCD Image Sensor
  • UXGA (2 Megapixel), 15fps
  • User-Programmable Area of Interest (AOI)

Model No



1/1.8” Interline UXGA color progressive CCD: ICX274AQ

Total Picture Element

1688 (H) x 1246 (V)

Active Picture Element

UXGA: 1624 (H) x 1236 (V)

Chip Size

8.5 (H) x 6.8 (V) mm

Cell Size

4.4 (H) x 4.4 (V) µm

Scanning System


Vertical Frequency (Frame Rate)

15.31668 Hz at full resolution 0.29261 to 61.26674 Hz adjustable via the communication Max. frame rate depends on the AOI setting Max. frame rate of the camera(61.26674) is 230 vertical resolution AOI setting

Horizontal Frequency

19.1761 kHz

Pixel Frequency

36.8181 MHz

Noise Level


- @ 8bit output

≤ 3 Digit (Gain 0 dB)

- @ 10bit output

≤ 12 Digit (Gain 0 dB)

- @ 12bit output

≤ 48 Digit (Gain 0 dB)

Minimum Scene Illumination

7.27 Lux at F1.2, 15.31668 Hz

Sync System


Video Output

Digital 8, 10 or 12 bit Raw Data or RGB 8 bit


IEEE802.3 (1000BASE-T)


GigE Vision® 1.2 and GenICam™ 2.0 compliant

Shutter Speed

Preset continuous mode: 1 useconds to 16,777,216 useconds Preset trigger mode: 1 useconds to 16,777,216 useconds Pulse width mode: 1 useconds to Unlimited


Auto iris lens, electronic iris and AGC (ON / OFF)


0 to 20.4 dB


Gamma 1.0 (Factory default) or uploadable gamma table

AOI Function

Programmable AOI setting via the communication

Smear Reduction

Selectable ON / OFF via the communication

Color Interpolation

Available on RGB output

White Balance Function

Auto, manual and push-to-set white balance is available on both Raw data output and RGB output

Trigger Mode

Edge preset trigger, Pulse width trigger (unlimited long exposure)


UART Communication through Ethernet port


One opto-isolated input and two open-collector outputs

Auto IRIS lens control

DC IRIS control input with video level target, peak/average and zone weight settings via the communication



- Input Voltage

+10.8 to +26.4 Vdc

- Consumption

< 5.00 W


35 (W) x 35 (H) x 50.6 (D) mm excluding connectors

Optical Filter

IR cut filter on

Optical Center Accuracy

Positional accuracy in H and V directions: +/- 0.3 mm Rotational accuracy of H and V: +/- 1.5 deg.


Aluminum (AC)

Lens Mount

C mount


RJ45 connector Power/IO connector: HR10A-7R-6PB (Hirose) or equivalent DC IRIS lens connector: M1951 (EMUDEN) or equivalent

Camera Mount Screws

Two 1/4” Tripod screw holes: (One on each top and bottom plate), Twelve M4 screws holes: (Four on each top and bottom plate, two on each side plate)


Approximately 120g

Operating Temperature


- Minimum

Environmental Temperature -5 deg. C

- Maximum

Camera housing temperature (top plate) shall not exceed 65 deg. C (This corresponds to an environmental temperature of approximately 35 deg. C)

Storage Temperature

Environmental Temperature: -30~ 65 deg. C


20 Hz to 200 Hz to 20 Hz (5 min. /cycle), acceleration 10G, 3 directions 30 min. each


Acceleration 38G, half amplitude 6 ms, 3 directions 3 times each

Standard Compliancy

EMS: EN61000-6-2, EMI: EN55011


RoHS Compliant

facebook.png twitter.png googleplus.png linkedin.png youtube.png pinterest.png