Access power controller - 8 fused non power-limited outputs provide 12VDC @ 10 amp

Altronix - AL1012ULACM View Larger Image (in new window)

Altronix : AL1012ULACM

Contact us for lowest price (800) 284-2288 , (858) 565-1101 Call Now [email protected]

The Altronix Model AL1012ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC non power limited fuse protected Fail-Safe and/or Fail-Secure outputs with a total of 10 amp continuous supply current. The fire alarm disconnect feature enables emergency egress in the event the fire alarm system is activated. It is individually selectable for any or all of the eight (8) outputs. Model AL1012ULACMCB is a PTC protected version of this unit.

 

Available Configurations Include:

AL1012ULACMJ Power Supply/Charger with Access power controller - 8 fused non power-limited outputs provide 12VDC @ 10 amp, outputs are individually selectable for Fail-Safe or Fail-Secure operation or as dry form "C" contacts, fire alarm disconnect is selectable by output, AC & battery monitoring, encl. 18”H x 14.5”W x 4.625”D, 115VAC input, UL Listed (UL294), cUL Listed.
AL1024ULACM Power Supply/Charger with Access power controller - 8 fused non power-limited outputs provide 24VDC @ 10 amp, outputs are individually selectable for Fail-Safe or Fail-Secure operation or as dry form "C" contacts, fire alarm disconnect is selectable by output, AC & battery monitoring, encl. 15.5”H x 12”W x 4.5”D, 115VAC input, UL Listed (UL294), cUL Listed, CSFM & MEA Approved.
AL1024ULACMJ Power Supply/Charger with Access power controller - 8 fused non power-limited outputs provide 24VDC @ 10 amp, outputs are individually selectable for Fail-Safe or Fail-Secure operation or as dry form "C" contacts, fire alarm disconnect is selectable by output, AC & battery monitoring, encl. 18”H x 14.5”W x 4.625”D, 115VAC input, UL Listed (UL294), cUL Listed.

AL1012ULACM features include:

  • Input 115VAC 60Hz rated @ 2.6 amp.
  • Power supply input options:
  • a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed).
  • b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10 amp total).
  • Eight (8) Access Control System trigger inputs.
  • Input options:
  • a) Eight (8) normally open (NO) inputs.
  • b) Eight (8) open collector inputs.
  • c) Any combination of the above.
  • 12VDC @ 10 amp supply current.
  • Eight (8) independently controlled outputs.
  • Output options:
  • Eight (8) Fail-Safe and/or Fail-Secure power outputs.
  • Eight (8) auxiliary power outputs (unswitched)
  • Output ratings:
  • - Fuses are rated @ 3.5 amp.
  • Filtered and electronically regulated outputs (built-in power supply).
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Fire Alarm disconnect input options:
  • a) Normally open (NO) or normally closed (NC) dry contact input.
  • b) Polarity reversal input from FACP signaling circuit.
  • Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC not evaluated by UL).
  • Short circuit and thermal overload protection.
  • Red LEDs indicate outputs are triggered (relays energized).
  • Green LED indicates FACP disconnect is triggered.
  • AC input and DC output LED indicators.
  • Built-in charger for sealed lead acid or gel type batteries.
  • AL400ULXB (Power Supply Board) maximum charge current 0.7 amp.
  • Automatic switch over to stand-by battery when AC fails.
  • Zero voltage drop when unit switches over to battery backup (AC failure condition).
  • Battery fail and battery presence supervision (form "C" contact).
  • Operating temperature: 0° C to 49° C ambient.
  • ACM8 board main fuse is rated at 10 amp.
  • BTU/Hr.: 61.42BTU/Hr.


facebook.png twitter.png googleplus.png linkedin.png youtube.png