Call Now: 1-800-284-2288 |
(discontinued)8 Relay and 4 Digital/Analog Input Module |
|
|
This product has been discontinued. For an alternative, please contact [email protected].
The ST-IO is a Cresnet® expansion module that provides eight low-voltage relay outputs and four digital/analog input ports. Typical applications include control of lighting, screens, drapes, and more. In "closure" mode, each input port will sense a contact closure signal from a door switch, motion sensor, etc., and can also accept analog 0-24 Volt DC signals when in "voltage" mode. The ST-IO may be used to provide a low-voltage control interface at a remote location, or may be rack mounted in the central equipment cabinet to expand the number of control system ports (ST-RMK rack mount kit sold separately). Communication with the control system is via a single Cresnet connection.
Available Configurations Include:
STI-IO | Cresnet Module with 8 Relays and 4 Analog/Digital Inputs - International Version, 230V. Includes PWI-1215 Power Supply |
Connectors | ||
RELAY OUTPUT 1 – 8 | (1) 16-pin 5mm detachable terminal block comprising (8) normally open, isolated relays; Rated 1 Amp, 30 Volts AC/DC maximum; 100µA, 100mV minimum |
|
DIGITAL IN 1 – 4 | (1) 5-pin 5mm detachable terminal block comprising (4) digital or analog input ports (referenced to GND); Digital Input (closure mode): Input threshold 2 Volts DC (±0.5VDC); input impedance 1k ohms to +5VDC; 5 Volt, 1k ohms pull-up resistor and protection diode per pin; Analog Input (voltage mode): Input threshold 2 Volts DC (±0.5VDC); voltage range 0-24 Volts DC; input impedance 44k ohms |
|
NET | (2) 6-pin RJ11 female, Cresnet slave ports, paralleled; Connect to Cresnet control network |
|
12VDC | (1) 2.5mm barrel DC power jack; 12 Volt DC power input (PW-1205 power pack included) |
|
Indicators | ||
PWR | (1) green LED, indicates power supplied from Cresnet network or local power pack | |
NET | (1) amber LED, indicates communication with Cresnet system | |
INPUT 1 – 4 | (4) red LEDs, indicate a high signal at each corresponding digital input port | |
RELAY 1 – 8 | (4) red LEDs, indicate a closure at each corresponding relay output port | |
Power Requirements | ||
Power Pack | 0.5 Amp @ 12 Volts DC; 120 Volts AC, 60 Hz power pack, model PW-1205, included |
|
Cresnet Power Usage | 6 Watts (0.25 Amp @ 24 Volts DC) with no power pack connected | |
Environmental | ||
Temperature | 41° to 113°F (5° to 45°C) | |
Humidity | 10% to 90% RH (non-condensing) | |
Enclosure | ||
Chassis | Metal, black finish | |
Faceplate | Extruded aluminum, black finish with polycarbonate label overlay | |
Mounting | Freestanding or 1U 1/2-width 19-inch rack-mountable (adhesive feet included, ST-RMK rack kit sold separately) | |
Dimensions | ||
Height | 1.80 in (46 mm); 1.70 in (44 mm) without feet |
|
Width | 7.07 in (180 mm) | |
Depth | 6.32 in (161 mm) | |
Weight | ||
1.96 lb (0.89 kg) | ||
INTERNATIONAL VERSION (230 VAC) | ||
STI-IO | ||
All the features and specifications of the ST-IO except: | ||
Power Requirements | ||
Power Pack | 0.5 Amp @ 12 Volts DC; 230 Volts AC, 50 Hz power pack, model PWI-1215, included |
|
Cresnet Power Usage | 6 Watts (0.25 Amp @ 24 Volts DC) with no power pack connected |
st-io.pdf | Datasheet |
Call Now: 1-800-284-2288 |
|||||
Email Us: sales@avsupply |
|||||
|