JAI CV-M10SX E 1/2" Monochrome Progressive Scan Camera With EIA And VGA
Offering Wholesale, OEM, USA / International, GSA Government / Educational, Reseller / Retail, & Quantity Prices and Specifications / Datasheets, Installation Guides, and Operational Manuals.
Price Documents
→ 1/2" progressive scan monochrome EIA (VGA) camera
→ Successor of the popular CV-M10BX/RS series
→ Improved sensitivity and smear performance
→ 782 (h) x 582 (v) square pixels for CCIR (SVGA) version
→ 659 (h) x 494 (v) square pixels for EIA (VGA) version
→ Single channel video output
→ Extremely short shutter speed, down to 1/917 000 sec. for CCIR (SVGA)
→ Internal, external HD/VD or random trigger synchronization
→ Edge pre-select (EPS) and pulse width control (PWC) trigger modes
→ Frame-delay readout
→ H reset and H non-reset trigger
→ Long time integration modes
→ WEN and Pixel clock output for easy interfacing
→ Setup by Windows 98/NT/2000 setup software via RS-232C
→ Scanning system: Progressive scan
→ CCD sensor: Monochrome 1/2" IT CCD
→ Sensing area: 6.61 (h) x 4.97 (v) mm
→ Frame rate (progressive) (CV-M10 SX EIA): 29.97 frames/sec. (525 lines/frame)
→ Line frequency (CV-M10 SX EIA): 15.734 kHz
→ Pixel frequency (CV-M10 SX EIA): 12.2727 MHz
→ Effective Pixels (CV-M10 SX EIA): 659 (h) x 494 (v)
→ Pixels in video output (CV-M10 SX EIA): 648 (h) x 486 (v)
→ Cell size: (CV-M10 SX EIA) 9.9 (h) x 9.9 (v) μm
→ Sensitivity on sensor: 0.05 Lux, Max gain, 50% video
→ S/N ratio: >56 dB (AGC off, Gamma 1)
→ Video output: Composite 1.0 Vpp, 75 Ω
→ Gamma: 0.45 or 1.0
→ Gain: Manual - automatic
→ Gain range: 0 to 15 dB
→ Synchronization: Int. X-tal., Ext HD/VD or random trigger
→ Scanning: Progressive
→ HD/VD input: 4V, TTL or 75 Ω terminated
→ HD/VD output: 4V from 75 Ω source
→ Trigger input: 4V, TTL or 75 Ω terminated
→ EEN and WEN output: 4V from 75 Ω source
→ Pixel clock output: 4V from 75 Ω source
→ Trigger modes: Continuous, Edge pre-select (EPS), Pulse width control (PWC)
→ Trigger: HD synchronous or H reset
→ Shutter (EPS mode): EIA: 16 steps 1/30 to 1/800,000
→ Shutter (PWC mode): 1 H to 625 H
→ Long time exposure: 8 steps, 2 to 16 fiels
→ Functions controlled by RS-232C: Shutter, Trigger, Black level, Gain AGC level, White clip
→ Camera rear panel controls: Shutter, Trigger, Scan, Gamma, Gain
→ Vibration: 10 G (20 to 200 Hz in XYZ)
→ Shock: 70 G
→ Regulations: CE (EN50081-1, EN50082-1), FCC part 15
→ Operating temperature: -5°C to 45°C
→ Humidity: 20 - 80% non-condensing
→ Power: 12V DC ±10%. 5 W
→ Lens mount: C-mount
→ Dimensions: 40 x 50 x 80 mm (HxWxD)
→ Weight: 245 g
→ Successor of the popular CV-M10BX/RS series
→ Improved sensitivity and smear performance
→ 782 (h) x 582 (v) square pixels for CCIR (SVGA) version
→ 659 (h) x 494 (v) square pixels for EIA (VGA) version
→ Single channel video output
→ Extremely short shutter speed, down to 1/917 000 sec. for CCIR (SVGA)
→ Internal, external HD/VD or random trigger synchronization
→ Edge pre-select (EPS) and pulse width control (PWC) trigger modes
→ Frame-delay readout
→ H reset and H non-reset trigger
→ Long time integration modes
→ WEN and Pixel clock output for easy interfacing
→ Setup by Windows 98/NT/2000 setup software via RS-232C
→ Scanning system: Progressive scan
→ CCD sensor: Monochrome 1/2" IT CCD
→ Sensing area: 6.61 (h) x 4.97 (v) mm
→ Frame rate (progressive) (CV-M10 SX EIA): 29.97 frames/sec. (525 lines/frame)
→ Line frequency (CV-M10 SX EIA): 15.734 kHz
→ Pixel frequency (CV-M10 SX EIA): 12.2727 MHz
→ Effective Pixels (CV-M10 SX EIA): 659 (h) x 494 (v)
→ Pixels in video output (CV-M10 SX EIA): 648 (h) x 486 (v)
→ Cell size: (CV-M10 SX EIA) 9.9 (h) x 9.9 (v) μm
→ Sensitivity on sensor: 0.05 Lux, Max gain, 50% video
→ S/N ratio: >56 dB (AGC off, Gamma 1)
→ Video output: Composite 1.0 Vpp, 75 Ω
→ Gamma: 0.45 or 1.0
→ Gain: Manual - automatic
→ Gain range: 0 to 15 dB
→ Synchronization: Int. X-tal., Ext HD/VD or random trigger
→ Scanning: Progressive
→ HD/VD input: 4V, TTL or 75 Ω terminated
→ HD/VD output: 4V from 75 Ω source
→ Trigger input: 4V, TTL or 75 Ω terminated
→ EEN and WEN output: 4V from 75 Ω source
→ Pixel clock output: 4V from 75 Ω source
→ Trigger modes: Continuous, Edge pre-select (EPS), Pulse width control (PWC)
→ Trigger: HD synchronous or H reset
→ Shutter (EPS mode): EIA: 16 steps 1/30 to 1/800,000
→ Shutter (PWC mode): 1 H to 625 H
→ Long time exposure: 8 steps, 2 to 16 fiels
→ Functions controlled by RS-232C: Shutter, Trigger, Black level, Gain AGC level, White clip
→ Camera rear panel controls: Shutter, Trigger, Scan, Gamma, Gain
→ Vibration: 10 G (20 to 200 Hz in XYZ)
→ Shock: 70 G
→ Regulations: CE (EN50081-1, EN50082-1), FCC part 15
→ Operating temperature: -5°C to 45°C
→ Humidity: 20 - 80% non-condensing
→ Power: 12V DC ±10%. 5 W
→ Lens mount: C-mount
→ Dimensions: 40 x 50 x 80 mm (HxWxD)
→ Weight: 245 g
The JAI's CV-M10SX E is the successor of the popular CV-M10BX E and CV-M10RS E cameras with a resolution compatible with the SVGA format.
The CV M10SX E camera is a 1/2" progressive scan camera that offers a superb image quality in versatile applications such as machine vision, high speed video capturing, pattern recognition, etc.
All CVM10SX E camera settings are done via an RS 232C interface or by DIP switches on the rear panel.
Similar Models:
CV-M10SX C: 1/2" Monochrome Progressive Scan Camera with CCIR And SVGA