(discontinued)1/3" Monochrome Interlaced Scan Camera, CCIR Video Standard
|
|
By: JAI
CCD & CMOS Cameras
|
This product has been discontinued. For an alternative solution, please contact sales.
The JAI CV-A60C has the compact footprint of merely 44 x 66 mm (width x length) with a height of 29 mm.
The CV A60C offers S/N ratio >58dB, excellent sensitivity and smear performance. RS 232C control of all settings. Sevaral trigger modes including edge pre-select and pulse width control.
The target market for the CVA60C camera family is volume OEMs (Original Equipment Manufacturers) and high level System Integrators for Automated Imaging applications (e.g. industrial/medical equipment).
→ New compact size 1/2" and 1/3" monochrome CCD cameras
→ Improved sensitivity, dynamic range and smear performance
→ High S/N ratio up to 60 dB
→ Extended range of functions and options compared with CV-M50
→ Shutter speeds from Off to 1/10,000 sec.
→ Programmable exposure
→ Interlaced or non-interlaced scanning. Field or frame accumulation
→ Internal, external HD/VD or random trigger synchronization
→ Edge pre-select, pulse width control, start/stop trigger modes
→ Long time exposure with external VD pulse interval
→ Frame-delay read out in connection with pulse width controlled shutter
→ Exposure enable EEN, write enable WEN and pixel clock output
→ Short ASCII commands for fast mode setup via serial port
→ Setup by Windows 95/98/NT software via RS 232C
→ Resolution horizontal 570 TV lines
→ Video output Composite VS signal, 1.0 Vpp, 75 Ω
→ Gamma 0.45 or 1.0
CCIR |
752 (h) x 582 (v) pixels. EIA: 768 (h) x 494 (v) pixels |
Scanning system, CCIR |
625 lines 25 frames/sec |
CCD sensor CV-A60 |
Monochrome 1/3" IT CCD |
Sensing area, CV-A60 |
4.9 (h) x 3.7 (v) mm |
Effective pixels, CCIR |
752 (h) x 582 (v) |
Pixels in video output, CCIR |
737 (h) x 575 (v) |
Cell size, CV-A60, CCIR |
6.5 (h) x 6.25 (v) μm |
Sensitivity on sensor, CV-A60 |
0.05 Lux, Max gain, 50% video |
S/N ratio, CV-A60, CCIR |
58 dB |
Gain |
Manual - Automatic |
Gain range |
0 to 15 dB |
Accumulation |
Field-Frame |
Synchronization |
Int. X-tal. Ext HD/VD or random trigger |
Scanning |
2:1 interlaced, non-interlaced |
HD sync. input/output |
4 V, 75 Ω |
Trigger input |
4 V, 75 Ω |
WEN output (write enable) |
4 V, 75 Ω |
EEN out. (exposure enable) |
4 V, 75 Ω |
Pixel clock output |
4 V, 75 Ω |
Shutter |
(off), 1/100, 1/250, 1/500, 1/1,000, 1/2000, 1/4000, 1/10,000 sec. |
Pulse width control |
1.5 H to 1000 H |
Start/stop, CCIR |
1/50 to 1/10,000 sec. |
Long time exposure |
1 field to ∞ |
Programmable exposure |
2.5 H to 252.5 H |
Frame delay readout |
Time from PWC trigger input to ext. VD input |
Functions controlled by RS-232C |
Scanning format, Trigger mode,Shutter speed, Trigger/WEN polarity, Accumulation, Shutter mode, Programmable exposure, AGC level, White clip, Setup, Manual gain, AGC/manual gain, Internal/potentiometergain set, Gamma, Pixel clock, Commands and internal adjustments |
Functions controlled by DIP switches |
VD input/output, HD input/output, internal HD and VD 75 Ω termination on/off |
Operating temperature |
-5°C to 45°C |
Humidity |
20 - 80% non-condensing |
Storage temp./humidity |
-25°C to 60°C/20% - 90% |
Power |
12V DC ±10% 1.5 W |
Lens mount |
C-mount |
Dimensions |
29 x 44 x 66 mm (HxWxD) |
Weight |
150 g |
© 1996 - 2024 | All Rights Reserved