Call Now: 1-800-284-2288 |
4 Output Power Supply/Charger - 12VDC or 24VDC @ 2.5 amp, fused Class 2 power-limited outputs |
|
|
The Altronix AL300ULPD4 is a multi-output power supply/charger that converts a 115VAC/60Hz input into four (4) Class 2 Rated 12VDC or 24VDC power limited outputs.
Available Configurations Include:
AL300ULPD8 | 8 Output Power Supply/Charger - 12VDC or 24VDC @ 2.5 amp, fused Class 2 power-limited outputs, AC & battery monitoring, encl. 13.5”H x 13”W x 3.25”D, 115VAC input, UL Listed (UL294/UL603/UL1069/UL1481), cUL Listed. |
AL300ULXPD16 | 16 Output Power Supply/Charger - 12VDC or 24VDC @ 2.5 amp, fused Class 2 power-limited outputs, AC & battery monitoring, encl. 15.5”H x 12”W x 4.5”D, 115VAC input, UL Listed (UL294/UL603/UL1069/UL1481), cUL Listed. |
AL400ULPD4 | 4 Output Power Supply/Charger - 12VDC @ 4 amp or 24VDC @ 3 amp, fused Class 2 power-limited outputs, AC & battery monitoring, encl. 13.5”H x 13”W x 3.25”D, 115VAC input, UL Listed (UL294/UL603/UL1069/UL1481), cUL Listed. |
AL400ULPD8 | 8 Output Power Supply/Charger - 12VDC @ 4 amp or 24VDC @ 3 amp, fused Class 2 power-limited outputs, AC & battery monitoring, encl. 13.5”H x 13”W x 3.25”D, 115VAC input, UL Listed (UL294/UL603/UL1069/UL1481), cUL Listed. |
AL400ULXPD16 | 16 Output Power Supply/Charger - 12VDC @ 4 amp or 24VDC @ 3 amp, fused Class 2 power-limited outputs, AC & battery monitoring, encl. 15.5”H x 12”W x 4.5”D, 115VAC input, UL Listed (UL294/UL603/UL1069/UL1481), cUL Listed. |
AL300ULPD4 features include:
Input 115VAC, 60Hz, 3.5 amp.
Input fuse rated @ 3.5 amp/250V.
12VDC or 24VDC selectable output.
Burglar Alarm Applications (UL 603):
12VDC = 10VDC-13.2VDC.
24VDC = 20VDC-26.4VDC.
12VDC or 24VDC @ 2.5 amp supply current.
Four (4) Class 2 Rated fuse protected power limited outputs.
Outputs are rated @ 3.5 amp.
Filtered and electronically regulated outputs.
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.
Maximum charge current 0.7 amp.
AC fail supervision (form "C" contacts).
Low battery supervision (form "C" contacts).
Battery presence supervision (form "C" contacts).
Visual Indicators:
AC input, DC output and Battery LED indicators.
Operating temperature: 0° C to 49° C ambient.
12VDC: 14.71 - 16.63BTU/Hr.
24VDC: 29.43 - 32.41BTU/Hr.
System AC input VA requirement: 402.5VA.
al300ulpd4.pdf | Datasheet |
Call Now: 1-800-284-2288 |
|||||
Email Us: sales@avsupply |
|||||
|