Search

NSM5300 Series Network Storage Manager with 400 MBPS Recording Throughput, Up to 72 TB of Raw Capacity, RAID 6

Contact us for lowest price (800) 284-2288 , (858) 565-1101 Call Now [email protected]

The NSM5300 Series delivers industry leading performance and innovation for mission-critical storage needs. The combination of high performance, scalable hardware design and advanced software capabilities enables the NSM5300 to meet the unique storage needs of physical security and surveillance applications.

Hardware Built for Performance, Reliability, and Scalability

The demands of surveillance applications place unique strains on storage subsystems. Storage systems require the bandwidth and capacity to keep up with incoming streams. They must also simultaneously manage all other common disk and RAID functions. In addition, physical security applications are almost always mission critical. Any downtime, degraded performance for routine maintenance, or loss of recorded footage is extremely disruptive to the organization’s physical security mission.

The NSM5300 has been engineered to meet these unique performance and reliability demands. Custom hardware components, to eliminate common performance choke points to a patented scheme for writing content to a disk drive, have been specifically designed to deliver sustained high throughput for recording and playback. The NSM5300 is capable of a maximum of 400 Mbps of throughput for incoming streams while delivering 32 simultaneous playback streams per storage pool. This performance is maintained whether the system is operating under normal conditions, dealing with disk drive errors, or rebuilding the RAID array.

The NSM5300 improves the total cost of ownership and energy efficiency by consolidating disparate components into a single chassis. The 400 Mbps throughput provides double the improvement over Pelco’s first generation integrated recorder, allowing users to service far more data streams in one storage unit than previously possible. In addition, with the integration of the storage controller functionality into the storage chassis, cost and energy efficiency is optimized by eliminating the cost of additional servers and the associated heating, ventilation, and cooling costs. Finally, the use of lower power components and adaptive cooling inside the chassis manage power dissipation based on load requirements.

Reliability is enhanced through the use of redundancy at all common failure points. An USB Flash drive is used to host the operating system for higher reliability than traditional hard disk drives. To mitigate any downtime resulting from USB Flash drive errors, the database is striped across the storage array. The RAID 6 storage configuration provides double parity protection of recorded data. The hard drive bay is cooled through the use of high capacity, redundant fans to ensure that the drives are kept at an optimum operating temperature. Finally, fully redundant power supplies guard against any power supply failure.

As with any system, maintenance is an important and vital part of sustained operation. The NSM5300 incorporates various innovations to make maintenance more efficient and to allow the system to continue operating at peak performance levels. Temperature sensors throughout the chassis detect possible air-flow obstruction or clogged intake filters. The use of enterprise-class SAS® technology provides advanced enclosure management and monitoring. Notifications of potential or actual issues are transmitted to the specified user interfaces for action.

Software Built for Flexibility, Reliability, Cost Optimization

In addition to unique strains placed on hardware components, surveillance applications also demand innovations in software. Recording software must accommodate automatic failover should a catastrophic failure occur. Recording software must deal with file fragmentation caused by overwrite, locking of video clips, and managing metadata associated with alarms and events. Finally, recording software must deal with the escalating cost of storage by finding innovative ways to manage recorded content. This ensures that the user extracts the most value from the cost of the storage subsystem.

The NSM5300 supports the pooling of multiple recorders to provide for automatic retention balancing and failover. Up to six NSM5300 nodes can be placed into the same storage pool. One of the NSM5300s in the pool acts as the master and manages the assignment of incoming streams, health monitoring, and redistribution of the recording load. Should a unit fail, the given streams are automatically redistributed to the remaining units in the storage pool. When the failed unit is brought back on line, the recording load is redistributed to balance the video retention period across the recording pool. This capability also allows users to dynamically add additional storage to a pool as their retention needs change. Single NSM5300s can be monitored by another NSM5300 or an entire storage pool when the single NSM5300 cannot be incorporated into a standard storage pool.

For mission-critical applications where business continuity is essential, the NSM5300 supports redundant recording. Independent schedules can be created on both the primary and redundant storage pools to ensure that the most vital data is duplicated across physical boundaries.

The NSM5300 incorporates an improved version of Pelco’s patented EnduraStor™ storage optimization technology. EnduraStor was developed to manage the cost of storing high resolution, high-frame rate video by leveraging the fact that the value of recorded video is typically higher immediately following an incident. Organizations are capable of specifying a desired delay period during which all recorded video will be kept at 30 images per second (25 ips for PAL). As the age of video available on hard disk drives exceeds the delay period, it is automatically pruned to a lower frame rate, thus freeing up storage capacity for new data. The NSM5300 incorporates advancements in the EnduraStor algorithm, which gives administrators the option of classifying the priority level of alarm or event video to retain the full frame rate.

The NSM5300 is built upon the proven stability and robustness of its Linux®-based operating system. It utilizes an XFS file system and automated defragmentation routines to keep the database from becoming fragmented. XFS has been proven to be a superior file format for the rigors of surveillance recording applications than an NTFS file system, which is standard with Windows®-based recorders.

The NSM5300 incorporates a number of diagnostic monitoring functions that serve vital roles in notifying operators of potential problems and failures. Integrated diagnostics utilize on-board LED indicators to display warnings and failures on the NSM5300 and then it reports these failures to operators. The NSM5300 monitors and provides warning messages for items such as retention time issues, accumulation of software errors, network errors that result in packet loss, and changes to network link speeds. It also monitors and reports hardware diagnostics such as temperatures approaching established thresholds, hard disk drive failures, fan failures, power supply failures, or when a stream or a NSM5300 is off line. Finally, the NSM5300 can communicate to an APC Smart-UPS® series uninterruptable power supply to provide battery status information and initiate a graceful shutdown if the available charge falls below its designated threshold.

All models come with powercords for US, EU and UK and a rack mount kit.

Available Configurations,

NSM5300-24 Network Storage Manager with 24 TB raw capacity

NSM5300-48 Network Storage Manager with 48 TB raw capacity

NSM5300-72 Network Storage Manager with 72 TB raw capacity

Recording Throughput up to 400 Mbps Meets Demanding Performance Requirements for Write-Intensive Applications

Hardware Designed to Eliminate Single Points of Failure, Including Redundant Fans, Power Supplies, and RAID 6 Storage for Optimum Reliability

Pooled Storage Management Provides Automatic Distributed Load Balancing and Active-Active Failover Within a Storage Pool to Ensure Continued Recording if Catastrophic Failure Occurs

Hot Standby Failover Provides Redundancy in Installations Where Storage Pooling Cannot Be Utilized.

Multicast Recording Support Allows for Recording of Multicast Data Streams for Restricted Bandwidth Scenarios

Redundant Recording Ensures Duplication of Vital Data for Mission-Critical Applications

Built-in EnduraStor™ Storage Management Increases Storage Efficiency by Pruning Recorded Streams Based on Age and Priority

Ability to Serve 32 Simultaneous Playback Streams Per Storage Pool

Performance Levels Maintained in Normal and RAID Error Conditions

Built-in Diagnostic Monitoring Provides Preventative Maintenance and SNMP Monitoring

Reduced Cost of Ownership and Increased Energy Efficiency Through Consolidation of Multiple Hardware Components into a Fully Integrated Chassis

VideoXpert Ready. Migrate to VideoXpert, bringing your products forward into a next generation VMS

SYSTEM

Operating System Linux

RAID Level RAID 6

Effective Capacity

NSM5300-24 18.166 TB

NSM5300-48 36.356 TB

NSM5300-72 54.549 TB

Drive Interface SAS/SATA II

Recommended PC Requirements

Web Browser Microsoft® Internet Explorer® 6.x (or later) with Adobe® Flash® Player 10 (or later)

NETWORK

Interface 2, 1 Gbps Ethernet RJ-45 ports (1000Base-T)

Auxiliary Interfaces

USB 2.0 3 ports (1 front, 2 rear)

VGA 2 ports (1 front, 1 rear)

POWER

Power Input 100 to 240 VAC, 50/60 Hz, autoranging

Power Supply Internal, dual-redundant, hot swappable

ENVIRONMENTAL

Operating Temperature 10° to 35°C (50° to 95°F) at unit air intake

Storage Temperature –40°to 65°C (–40° to 149°F)

Operating Humidity 10% to 80% relative humidity

Maximum Altitude

Operating 3,048 m (10,000 ft)

Storage 12,000 m (39,370 ft)

Maximum Vibration Operating 0.26 Grms at 5 Hz to 350 Hz (all operation orientations)

Storage 1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested)

Note: The temperature at the unit air intake, measured at the front of the bezel, can be significantly higher than room temperature. Temperature is affected by rack configuration, floor layout, air conditioning strategy, and other issues. To prevent hard disk drive failure and unit damage, make sure the temperature at the air intake of the unit is continuously within the operating temperature range.

PHYSICAL

Construction Steel cabinet

Finish

Front Panel Gray metallic

Chassis Steel finish

Dimensions (without rails) 75.5 x 48.3 x 8.8 cm (29.8" D x 19.0" W x 3.5" H)

Unit Weight

Empty (without drives) 10.3 kg (22.7 lb)

Loaded (with drives) 32.5 kg (71.5 lb)

Mounting Options Rack, 2 RU per unit (rack rails and hardware are supplied)

CERTIFICATIONS/RATINGS

CE, Class A

FCC, Class A

UL/cUL Listed

RCM

CCC

KC

NOM



facebook.png twitter.png googleplus.png linkedin.png youtube.png
Prices and specifications subject to change without notice.