Search

Telecentric lens for 4k line scan cameras, magnification 0.159x, mount F

Opto Engineering - TC4K180-F View Larger Image (in new window)

Opto Engineering : TC4K180-F

Contact us for lowest price (800) 284-2288 , (858) 565-1101 Call Now [email protected]
Working distance: distance between the front end of the mechanics and the object. Set this distance within ±3% of the nominal value for maximum resolution and minimum distortion. Working f-number (wf/N): the real f-number of a lens in operating conditions. Maximum angle between chief rays and optical axis on the object side. Typical (average production) values and maximum (guaranteed) values are listed. Percent deviation of the real image compared to an ideal, undistorted image. Typical (average production) values and maximum (guaranteed) values are listed. At the borders of the field depth the image can be still used for measurement but, to get a very sharp image, only half of the nominal field depth should be considered. Pixel size used for calculation is 7 μm. Object side, calculated with the Rayleigh criterion with λ= 520 nm FD stands for Flange Distance (in mm), defined as the distance from the mounting flange to the camera detector plane. Indicates the availability of an integrated camera phase adjustment feature. Measured from the front end of the mechanics to the camera flange.
Main optical specifications
Magnification(x)0.159
Image width(mm)28.7
Max sensor size4k
Object field of view
Line 2k-5µm(mm)64.40
Line 2k-7µm(mm)90.19
Line 4k-5µm(mm)128.81
Line 4k-7µm(mm)180.31
Advanced optical specifications
Working distance (1)(mm)254.0
Working ƒ/N (2)16
Telecentricity typical (max) (3)(deg)< 0.08 (0.10)
Distortion typical (max) (4)(%)< 0.08 (0.10)
Depth of field (5)(mm)66.50
Resolution (6)(μm)64
Mechanical specifications
Mount (7)F
Phase adjustment (8)Yes
Length (9)(mm)522.4
Width(mm)208
Height(mm)64
Mass(g)3455


facebook.png twitter.png googleplus.png linkedin.png youtube.png